Sponsored Links
-->

Friday, March 2, 2018

Electrical Safety - Electrical Safety Testing - Electrical Safety ...
src: i.ytimg.com

Electrical safety testing is essential to ensure safe operating standards for any product that uses electricity. Various governments and agencies have developed stringent requirements for electrical products that are sold world-wide. In most markets it is mandatory for a product to conform to safety standards promulgated by safety and standard agencies such as UL, CE, VDE, CSA, BSI, CCC and so on. To conform to such standards, the product must pass safety tests such as the high voltage test (also called as Dielectric voltage-withstand test or high potential test), Insulation Resistance Test, Ground (Earth) Bond & Ground Continuity Test & Leakage Current Test (also called as Line Leakage Test, Earth Leakage Current Test, Enclosure Leakage Current Test or Patient Leakage Current Test). These tests are described in IEC 60335, IEC 61010 and many other national and international standards.

In general, IEC 60335 is the most widely applied standard for electrical safety testing, especially for domestic appliances. Many safety testing standards in the world have been based on it. To safeguard workplace health and safety, many sections of the Occupational Health and Safety Regulation provide guidelines on electrical safety and the appropriate equipment required to work on low and high voltage electrical appliances.


Video Electrical safety testing



Safety tests

High Voltage Test (Dielectric Voltage-withstand Test)

This test is carried out by applying a significantly higher than operating voltage to the device under test. In this test, the insulation of a product, stressed to a greater extent than under normal operating conditions, should not be breached for the product to pass. In most cases, the device is stressed to twice its normal operating voltage. During type testing, i.e. testing during designing a product or for a double insulated product, however, much larger voltage may be applied. For all electrical products, the high voltage test is a universal test, meaning that every unit should pass before it can be used.

Insulation Resistance Test

This test is to measure the total resistance of a product's insulation by applying a voltage of 500 V - 1000 V for low voltage systems. The minimum acceptable value of resistance for a product to pass an insulation resistance test is 1 megohm (1000 k?). The insulation resistance test is not a substitute for the high voltage test. Many standards and safety agencies have specified this is a universal test for all products. This test may also be carried out after every maintenance procedure or repair.

Earth Continuity Test

This test is performed by measuring the resistance between the third pin (ground) and outside metal body of the product under test. The maximum acceptable value is generally 0.5 ohms although certain standards may specify 0.1 ohms. This test is generally carried out at a slightly higher current (e.g. 25-60 A) so that the ground bond circuit maintains safe voltages on the chassis of the product, even at a high current, before the circuit breaker trips. This test is essential so that the product does not cause an electric shock resulting from insulation failure. In India current specified is 16 A so the test is done at double of the current i.e. 32 A.

Leakage Current Test (Line Leakage Test)

This test is to measure the undesirable leakage current that flows through or across the surface of the insulation or the dielectric of a capacitor. This test is generally carried out at 100%-110% of the rated input voltage of the product under test. The maximum acceptable limit of a leakage current is generally 210 micro amperes. At first, this test was mandatory for medical devices only.

Visual inspection:

This is where the electrician will survey the electrical installation before he/she commences with the electrical testing. The visual inspection will highlight broken or cracked devices, where devices may have been installed in the wrong location, or if there have been overloading or over heating problems.

Electrical testing with the use of electrical test meters, including:

Dead testing

Continuity testing: a test to check if there are any badly connected conductors (wires)

Insulation resistance testing: this test is to make sure that the electrical insulation material surrounding the conductors is intact.

Polarity: this test is to check that the connection are connected in the right sequence

Earthing arrangement testing: this check is to make sure that the earthing arrangement complies with regulations and that all connections are sound.

Live testing

Earth fault loop impedance testing: this test is to check that if a fault did occur, that the system meets requirements to cause a disconnection of the supply within the time limit specified

RCD testing: on modern electrical systems RCD's and RCBO's are regularly fitted, these devices react to electricity missing from the circuit or installation such as when a person is receiving an electric shock as the electricity passes through his body to the ground (earth).

The competent person will then issue an Electrical Installation Condition Report (EICR) also known as Periodic Inspection and Testing Report (PIR) detailing any observed damage, deterioration, defects, dangerous conditions and any non-compliances with the present-day safety standard that might give rise to danger.

If anything dangerous or potentially dangerous is found, the overall condition of the electrical installation will be declared to be 'unsatisfactory', meaning that remedial action is required without delay to remove the risks to those in the premises.


Maps Electrical safety testing



References


Rigel Medical introduces new electrical safety analyzer with ...
src: 1technation.com


See also

  • Portable appliance testing

Brisbane Electrical Safety Testing - Video Dailymotion
src: s2.dmcdn.net


External links

  • Electrical Safety chapter from Lessons In Electric Circuits Vol 1 DC book and series.